217 lines
9.2 KiB
HTML
217 lines
9.2 KiB
HTML
|
|
<!doctype HTML public "-//W3C//DTD HTML 4.0 Frameset//EN">
|
|
<html>
|
|
<head>
|
|
<meta http-equiv="Content-Type" content="text/html; charset=windows-1252">
|
|
|
|
|
|
<meta name="generator" content="Adobe RoboHelp 9">
|
|
<title>PC Control Groups</title>
|
|
<!--[if lt IE 5.5000]><style type="text/css">@import "/wiki/skins/monobook/IE50Fixes.css";</style><![endif]-->
|
|
<!--[if IE 5.5000]><style type="text/css">@import "/wiki/skins/monobook/IE55Fixes.css";</style><![endif]-->
|
|
<!--[if IE 6]><style type="text/css">@import "/wiki/skins/monobook/IE60Fixes.css";</style><![endif]-->
|
|
<!--[if IE 7]><style type="text/css">@import "/wiki/skins/monobook/IE70Fixes.css?1";</style><![endif]-->
|
|
<!--[if lt IE 7]><script type="text/javascript" src="/wiki/skins/common/IEFixes.js"></script>
|
|
<meta http-equiv="imagetoolbar" content="no" /><![endif]-->
|
|
<!-- Head Scripts -->
|
|
<link rel="stylesheet" href="HtmlHelp.css" type="text/css">
|
|
|
|
<style title="hcp" type="text/css">
|
|
<!--
|
|
span.hcp1 { font-weight:bold; }
|
|
p.hcp2 { margin-bottom:0; }
|
|
li.hcp3 { list-style:none;
|
|
display:inline; }
|
|
-->
|
|
</style>
|
|
</head>
|
|
|
|
<body class="ns-0 ltr">
|
|
<div id="globalWrapper">
|
|
<div id="column-content">
|
|
<div id="content">
|
|
<h1 class="firstHeading">PC Control Groups</h1>
|
|
<div id="bodyContent">
|
|
<p id="siteSub">PC Control Groups can be used to monitor
|
|
and control groups of control parameters i.e. mutes, faders
|
|
and so on, within the system. Each PC control group can
|
|
be associated with any number of control parameters which
|
|
are of the same type and in the same range. The PC control
|
|
group exposes a single control which can be placed on
|
|
a custom control panel. The value of this control is determined
|
|
by the values of the control parameters in the group.
|
|
The PC must be online to the system in order for the control
|
|
panels to be monitored. This is a useful feature where
|
|
there are 2 London devices performing the same action
|
|
(dual redundancy) since the PC control group will allow
|
|
you to monitor and control the same control parameters
|
|
on each London device.</p>
|
|
<p> </p>
|
|
<div class="editsection" style="float: right; margin-left: 5px;">
|
|
<h2>Creating a PC Control Group</h2>
|
|
<p>There are 2 ways in which to create a PC control
|
|
group.</p>
|
|
<p> <br>
|
|
1. <span class="hcp1">Create an empty
|
|
PC control group</span> by selecting it from the Panel
|
|
Menu. This displays the following dialog:</p>
|
|
<p> <br>
|
|
<img src="Create_pc_control_group.jpg" alt="Image:Create pc control group.jpg" title="Image:Create pc control group.jpg" style="border-width: 2px;
|
|
border-style: solid; margin-top: 0px; margin-bottom: 0px;
|
|
margin-left: 0px; margin-right: 0px;" width="380" height="421" border="2"></p>
|
|
<p> <br>
|
|
To then add controls to this group, drag the control
|
|
and drop it onto the control group which can be found
|
|
in the design tree under "This Computer"</p>
|
|
<p> <br>
|
|
2. <span class="hcp1">Create a PC Control
|
|
Group from selected objects.</span> This creates a
|
|
PC Control Group and adds all of the selected parameters
|
|
on the active control panel to it. The same dialog
|
|
as above is presented except the mode will already
|
|
have been determined. If any of the selected parameters
|
|
are read only then the PC Control Group is automatically
|
|
set as read only and cannot be changed.</p>
|
|
<p> </p>
|
|
<ul>
|
|
<li class="p"><p><span class="hcp1">Name
|
|
of PC Control Group:</span> Set a name for the
|
|
PC Control Group. It will then appear in the This
|
|
Computer folder in the <a href="MAINDesign_tree.htm">Design
|
|
Tree</a>. Drag it from the design tree and drop
|
|
it onto a control panel to control and monitor
|
|
the controls in the group. Selecting the control
|
|
group in the design tree will cause a green box
|
|
to be displayed around all of the controls in
|
|
that group to easilly identify its members.</p></li>
|
|
</ul>
|
|
<p> </p>
|
|
<ul>
|
|
<li class="p"><p><span class="hcp1">Force
|
|
PC Control Group to be read only:</span> Check
|
|
this box to set the exposed parameter as read
|
|
only. If any of the parameters in the group are
|
|
read only then this box will always be checked
|
|
and cannot be unchecked.</p></li>
|
|
</ul>
|
|
<p> </p>
|
|
<ul>
|
|
<li class="p"><p><span class="hcp1">Ignore
|
|
offline parameters:</span> Check this box for
|
|
the exposed parameter to ignore any parameters
|
|
which exist on devices which are no longer online
|
|
(the controls would appear greyed out on a control
|
|
panel).</p></li>
|
|
</ul>
|
|
<p> </p>
|
|
<ul>
|
|
<li class="p"><p><span class="hcp1">Binary
|
|
Mode:</span> Select binary mode when the parameters
|
|
in a group are on/off such as mutes, which would
|
|
normally be represented as buttons on a control
|
|
panel.</p></li>
|
|
</ul>
|
|
<p> </p>
|
|
<ul>
|
|
<li class="p"><p><span class="hcp1">Continuous
|
|
Mode:</span> Select continuous mode when the parameters
|
|
in the group have a range greater than on or off.
|
|
Note however, that controls must be in the same
|
|
range as each other in order to be in the same
|
|
control group.</p></li>
|
|
</ul>
|
|
<p> </p>
|
|
<ul>
|
|
<li class="p"><p class="hcp2"><span class="hcp1">Value changes:</span>
|
|
Sets the conditions for a change in the exposed
|
|
parameter.</p></li>
|
|
<li class="hcp3"><ul>
|
|
<li><p class="hcp2"><span class="hcp1">when
|
|
all parameters are equal</span> sets the exposed
|
|
parameter to the value of the parameters in
|
|
the group when they are all equal.<br>
|
|
</p></li>
|
|
<li><p class="hcp2"><span class="hcp1">to
|
|
value of last changed parameter</span> sets
|
|
the exposed parameter to the value of the
|
|
last parameter in the group to have changed.<br>
|
|
</p></li>
|
|
<li><p class="hcp2"><span class="hcp1">to
|
|
on when all parameters are on</span> sets
|
|
the exposed parameter to ON only when all
|
|
the parameters in the group are ON. The exposed
|
|
parameter will be OFF when all of the parameters
|
|
in the group are OFF. This applies to button
|
|
mode only.<br>
|
|
</p></li>
|
|
<li><p class="hcp2"><span class="hcp1">to
|
|
ON when more than X controls are ON</span>
|
|
sets the exposed parameter to ON when more
|
|
than X number of parameters in the group are
|
|
set to ON. The value for X is set in the "where
|
|
X is" edit box. This applies to button
|
|
mode only.<br>
|
|
</p></li>
|
|
<li><span class="hcp1">to average
|
|
of all parameters</span> sets the exposed
|
|
parameter to the average of all the parameters
|
|
in the group. This applies to fader mode only.</li>
|
|
</ul></li>
|
|
</ul>
|
|
<p> </p>
|
|
<ul>
|
|
<li class="p"><p><span class="hcp1">Where
|
|
X is:</span> Enter a value for the number of parameters
|
|
which must be ON before the exposed parameter
|
|
goes ON. This only applies when the <span class="hcp1">Value
|
|
changes</span> box is set to "<span class="hcp1">to
|
|
ON when more than X parameters are ON</span>".</p></li>
|
|
</ul>
|
|
<p> </p>
|
|
<ul>
|
|
<li class="p"><p class="hcp2"><span class="hcp1">When value changes:</span>
|
|
Determines the action to be taken on the parameters
|
|
in the group when the exposed parameter is changed.
|
|
This option is not available for read only PC
|
|
Control Groups.</p></li>
|
|
<li class="hcp3"><ul>
|
|
<li><p class="hcp2"><span class="hcp1">send
|
|
inverted current state</span> sets all parameters
|
|
in the group to the inverted value of the
|
|
exposed parameter. This applies to button
|
|
mode only.<br>
|
|
</p></li>
|
|
<li><p class="hcp2"><span class="hcp1">always
|
|
send off</span> sets all parameters in the
|
|
group to OFF. This applies to button mode
|
|
only.<br>
|
|
</p></li>
|
|
<li><p class="hcp2"><span class="hcp1">always
|
|
send on</span> sets all parameters in the
|
|
group to ON. This applies to button mode only.<br>
|
|
</p></li>
|
|
<li><span class="hcp1">maintain
|
|
offsets</span> sends the change in the exposed
|
|
parameter to all the parameters in the group
|
|
therefore maintaining offsets between parameters
|
|
in the group. This applies to fader mode only.</li>
|
|
</ul></li>
|
|
</ul>
|
|
<h2>Important Information</h2>
|
|
<ul>
|
|
<li class="p"><p class="hcp2">The
|
|
PC Control Group only exists on the PC<br>
|
|
</p></li>
|
|
<li>PC Control Groups can be found in the "This
|
|
Computer" folder in the <a href="MAINDesign_tree.htm">Design
|
|
Tree</a></li>
|
|
</ul>
|
|