<!doctype HTML public "-//W3C//DTD HTML 4.0 Frameset//EN">
|
||
<html>
|
||
<head>
|
||
<meta http-equiv="Content-Type" content="text/html; charset=windows-1252">
|
||
<meta name="generator" content="Adobe RoboHelp 9">
|
||
<title>Logic Display</title>
|
||
<link rel="StyleSheet" href="HtmlHelp.css" type="text/css">
|
||
<style title="hcp" type="text/css">
|
||
<!--
|
||
img.hcp1 { border:none; }
|
||
span.hcp2 { mso-ansi-language:EN-GB; }
|
||
b.hcp3 { font-weight:bold;
|
||
mso-bidi-font-weight:normal; }
|
||
-->
|
||
</style>
|
||
</head>
|
||
|
||
<body>
|
||
<h1 class="firstHeading" style="color: #008000; font-size: 18pt;"><span
|
||
style="color: #008000; font-size: 18pt;"><b style="font-weight: bold;">Logic
|
||
Display</b></span></h1>
|
||
<p><img src="BLU-GPX_BLU-GPZ/GPIO Images/LogicDisplay.JPG" alt="" border="0" class="hcp1"></p>
|
||
<p class="MsoNormal"><span class="hcp2">The Logic
|
||
Display gives the ability to write customised text out to the front panel
|
||
LCD display. When the ‘Write’ input transitions to the high state the
|
||
text configured in the properties will be written to the display and the
|
||
output of the Logic Display will go high.</span></p>
|
||
<p class="MsoNormal" style="mso-ansi-language: EN-GB;">If configured by
|
||
the properties (‘Clear on Reset’), the ‘Reset’ input can be used to clear
|
||
the customised text from the front panel LCD. When the ‘Reset’ input is
|
||
high the Logic Display output will be driven low.</p>
|
||
<p class="MsoNormal" style="mso-ansi-language: EN-GB;">If there are more
|
||
than one of the Logic Display objects in the design, the object which
|
||
is triggered last will take control of the display.  The output of
|
||
any previously triggered Logic Display Object will remain high until it
|
||
either reaches its timeout or its Reset input is taken high.</p>
|
||
<p class="MsoNormal" style="mso-ansi-language: EN-GB;"><img src="LogicDisplayProperties.JPG" alt="" border="0" class="hcp1"></p>
|
||
<p class="MsoNormal" style="mso-ansi-language: EN-GB;"> </p>
|
||
<p class="MsoNormal"><b class="hcp3"><span class="hcp2">LCD Text Top Line</span></b></p>
|
||
<p class="MsoNormal"><span class="hcp2">The text to
|
||
be displayed on the top line of the LCD (16 characters maximum).</span></p>
|
||
<p class="MsoNormal"><b class="hcp3"><span class="hcp2">LCD Text Bottom Line</span></b></p>
|
||
<p class="MsoNormal"><span class="hcp2">The text to
|
||
be displayed on the bottom line of the LCD (16 characters maximum).</span></p>
|
||
<p class="MsoNormal"><b class="hcp3"><span class="hcp2">Clear on Timeout</span></b></p>
|
||
<p class="MsoNormal"><span class="hcp2">Whether the
|
||
LCD text should be cleared on timeout or not. If set to ‘Yes’ the customised
|
||
text written to the LCD will be cleared after the configured timeout (see
|
||
below), the output will go low after the timeout and the LCD display will
|
||
revert to its standard behaviour.  </span></p>
|
||
<p class="MsoNormal"><b class="hcp3"><span class="hcp2">Timeout (in seconds)</span></b></p>
|
||
<p class="MsoNormal"><span class="hcp2">The timeout
|
||
period in seconds before the customised LCD text will get cleared and
|
||
the output of the Logic Display goes low.</span></p>
|
||
<p class="MsoNormal"><b class="hcp3"><span class="hcp2">Clear on Reset</span></b></p>
|
||
<p class="MsoNormal"><span class="hcp2">Whether the
|
||
customised LCD text should be cleared when the reset input goes high.
|
||
If set to ‘Yes’ the customised text written to the LCD will be cleared
|
||
when the ‘reset’ input goes high and the LCD display will revert to its
|
||
standard behaviour.  The output of the Logic Display object will
|
||
go low.</span></p>
|
||
  
|
||
<p class="MsoNormal"> </p>
|
||
</body>
|
||
</html>
|