<h1 class="firstHeading">Logic Outputs</h1>
|
|
<div id="bodyContent">
|
|
<p id="siteSub"> <br>
|
|
<img src="LogicOutputLED.JPG" alt="image:LogicOutputLED.JPG" title="image:LogicOutputLED.JPG" width="34" height="40" border="2" class="hcp1"></p>
|
|
<p>An LED control is the typical object that is assigned
|
|
to a logic output.</p>
|
|
<p>The logic outputs can be used to drive indicators or
|
|
third party devices. For example Logic Outputs can trigger
|
|
infra-red commands (to control DVD players etc) or power
|
|
relays to turn other equipment on or off. The logic output
|
|
can source 10mA, and sink 60mA.</p>
|
|
<p> </p>
|
|
<ul>
|
|
<li class="p"><p>Current source:</p></li>
|
|
</ul>
|
|
<p>This is intended for LEDs. The unit can supply up to
|
|
10.5mA at around 5V. An LED can be connected directly
|
|
without the need for a current limit resistor. When assigning
|
|
the Control or LED to the port in London Architect, set
|
|
the control port for normal mode.</p>
|
|
<p><img src="Current_source.jpg" alt="Image:Current source.jpg" title="Image:Current source.jpg" width="261" height="165" border="2" class="hcp1"></p>
|
|
<p> </p>
|
|
<ul>
|
|
<li class="p"><p>Current sink:</p></li>
|
|
</ul>
|
|
<p>This is intended for relays and higher power devices.
|
|
The unit can sink up to 60mA from an external supply.
|
|
If more current is driven into the port, the control port
|
|
automatically decreases its ability to sink current, protecting
|
|
the circuitry. As there is hysteresis within this circuit,
|
|
the full sink capability will not return until current
|
|
is decreased to below 60mA. When assigning the Control
|
|
or LED to the port in London Architect, set the control
|
|
port for inverted mode.</p>
|
|
<p><img src="Current_sink.jpg" alt="Image:Current sink.jpg" title="Image:Current sink.jpg" width="262" height="165" border="2" class="hcp1"></p>
|
|
<p> </p>
|
|
<h2>See Also</h2>
|
|
<p><a href="BLU-GPX_BLU-GPZ/Assigning_Control_Ports.htm">Assigning
|
|
Control Ports</a></p>
|
|
<p>Assignment of Logic Outputs is similar to assigning
|
|
control inputs.</p>
|
|
<p>When assigning this object to the control port, a dialog
|
|
will ask if you want the action to be:</p>
|
|
<ul>
|
|
<li class="p"><p><span class="hcp2">Normal</span>
|
|
(Control or LED in the ON state, causing the logic
|
|
port to go High, +5v)</p></li>
|
|
</ul>
|
|
<p>or</p>
|
|
<ul>
|
|
<li class="p"><p><span class="hcp2">Inverted</span>
|
|
(Control or LED in the ON state, causing the logic
|
|
port to go Low, 0v).</p></li>
|
|
</ul>
|
|