<h1 class="firstHeading">BNC Sync</h1>
<p><img src="buddylink.jpg" alt="Image:buddylink.jpg" border="0"></p>
<p>Film studios, broadcast and theatres can benefit from the external word
clock sync capability of the London Series via the BLU-800/BLU-805/BLU-806
and BLU-320/BLU-325/BLU-326
rear panel BNC IN connectors. &#160;The supported sync frequencies are
48kHz, 48kHz pull-down (47.952kHz), 96kHz and 96kHz pull-down (95.904kHz).
&#160;Synchronizing the Soundweb London internal DSP processing clock
to the House clock avoids having to use Sample Rate Conversion, resulting
in superior audio.</p>
<h1>Operation - To set up a system to use an external word clock as the
master clock for the BLU link ring</h1>
<ul type="disc">
<li><p>Set 'Sync to BNC' or 'Sync to BLU link' in the <a href="Device&#32;Properties&#32;Pane.html">properties</a>
for the device. </p></li>
<li><p>The BLU-800 or BLU-320 by default will sync to <a href="Cobranet&#32;Information.html">CobraNet</a>
if there is a valid CobraNet connection, otherwise they will sync
to BNC or BLU link. &#160;The BLU-805 or BLU-325 by default will sync
to AVB if there is a valid AVB connection, otherwise they will sync
to BNC or BLU link. The BLU-806 or BLU-326 by default will sync to
BNC or BLU link since the DANTE card will then sync externally from
the device clock. If there is neither a valid CobraNet or AVB connection
these devices will then sync to&#160;the <a href="BLU_link.html">BLU
link</a> bus, this can be seen on the control panel for the device.</p></li>
</ul>
<p class="hcp1">&#160;&#160;<img src="PanelSyncBLULink.png" alt="" border="0" class="hcp2"></p>
<ul type="disc">
<li>Set 'Sync to BNC' or 'Sync to BLU link' in the <a href="Device&#32;Properties&#32;Pane.html">properties</a>
for the device. The BNC can be selected as the word clock for the
BLU-800 or BLU-320. &#160;More than one device can be selected to
sync to BNC, &#160;&#160;BNC Sync will be indicated on the device
control panel.</li>
</ul>
<p class="hcp3"><img src="BNC_Sync.png" alt="" border="0" class="hcp2"></p>
<ul type="disc">
<li><p>The word clock can be applied to all BNC devices. &#160;This
means that if one of the BNC devices loses its word clock (e.g. BNC
cable has been pulled) the system will continue to be synchronised
to the word clock via another device.</p></li>
<li><p>The Mastership Priority of the BNC units must be set to a higher
value than all other units which do not have Sync to BNC selected
in the properties, the BNC device with the highest priority will be
the master for the BLU link ring.</p></li>
</ul>
<p class="hcp3"><img src="BNC_Master.bmp" alt="" border="0" class="hcp2"></p>
<ul type="disc">
<li><p>If this is not the case then London Architect will prevent you
from going online. Mastership priority is set on the <a href="Device&#32;Control&#32;Panels.html">device
control panel</a>, &#160;&#160;254 is the highest priority, 0 is the
lowest. </p></li>
</ul>
<p style="color: #ff0000;"><img src="BNC_Priority_Warning.bmp" alt="" border="0" class="hcp2"></p>
<ul type="disc">
<li><p>If the BNC input is invalid (cable missing or incorrect word
clock) the device will synchronise to the <a href="BLU_link.html">BLU
link</a> bus. &#160;The control panel for the device will indicate
both BNC and Error to indicate that there is an invalid word clock.</p></li>
</ul>
<p class="hcp1"><img src="BNC_Error.png" alt="" border="0" class="hcp2">I</p>
<ul type="disc">
<li><p><span class="hcp4">DO NOT USE COBRANET</span>
<span class="hcp4">OR AVB</span> on any devices which
synchronise to an external word clock as the CobraNet (or AVB) clock
will not be synchronised to this clock and it would produce undesirable
audio effects. &#160;A yellow warning triangle will be shown on the
CobraNet or AVB nodes of the device icon of CobraNet or AVB devices
where Sync to BNC or Sync to BLU link has been selected in the device
properties. &#160;</p></li>
<li><p>Dante networked audio can be used on devices which sync to external
word clock as it does support this. &#160;However it does not support
the pull-down frequencies. &#160;Under this condition the Dante card
&#160;will not be synchronised to the device clock and it would produce
undesirable audio effects. &#160;A yellow warning triangle will be
shown on the Dante nodes of the device icon where Sync to BNC or BLU
link has been selected with pull-down frequencies in the device properties.</p></li>
</ul>
<p class="hcp1"><img src="Coba_Warning.png" alt="" border="0" class="hcp2"> &#160;&#160;&#160;&#160;&#160;&#160;<img src="AVB&#32;Files/AVB&#32;Warning&#32;Triangles.PNG" alt="" border="0" class="hcp2"> &#160;&#160;&#160;&#160;&#160;<img src="DANTE/DanteWarning.PNG" alt="" border="0" class="hcp2"></p>
<ul type="disc">
<li><p>The BLU-160 and BLU-120 will default to synchronise to BLU link
at all times since they do not use CobraNet, AVB or DANTE. &#160;The
sample rate and sample rate pull-down is selected in <a href="Device&#32;Properties&#32;Pane.html">properties</a>
for the device. &#160;</p></li>
<li><p>The BLU-100, BLU-101 and BLU-102 will also default to synchronise
to BLU link. &#160;&#160;The 48kHz sample rate and sample rate pull-down
is selected in <a href="Device&#32;Properties&#32;Pane.html">properties</a>
for the device.</p></li>
<li><p>The same sample rate must be selected for every device in the
design otherwise London Architect will not permit you to go online
and will display a warning.</p></li>
</ul>
<p class="hcp1"><img src="SampleRateWarning.png" alt="" border="0" class="hcp2"></p>
<ul type="disc">
<li><p>The <a href="BLU-BIB_Break_In_Box_for_Blu_link.htm">BLU-BIB</a>
and <a href="BLU-BOB.htm">BLU-BOB</a> will auto-switch and lock to
whatever sample rate frequency is detected on their ports. &#160;</p></li>
</ul>
<p style="margin-left: 40px; font-weight: bold; color: #000000;">IMPORTANT,
PLEASE NOTE</p>
<p style="margin-left: 40px; color: #000000; font-weight: normal;">BLU-BOBs and BLU-BIBs
with version numbers below v1.05 are not compatible with BLU link pull-down
sample rates. &#160;<span lang="EN-US" xml:lang="EN-US" class="hcp5">If
the design requires pull-down and you have a pre v1.05&#160;BLU-BIB or
BLU-BOB, please contact Customer Services at </span><span style="font-family: 'Franklin Gothic Medium', sans-serif;
mso-fareast-font-family: Calibri;
mso-fareast-theme-font: minor-latin;
mso-bidi-font-family: 'Times New Roman';
color: #17365D;
mso-ansi-language: EN-GB;
mso-fareast-language: EN-GB;
mso-bidi-language: AR-SA;"><a
href="mailto:bss.support@harman.com">bss.support@harman.com</a></span><span lang="EN-US" xml:lang="EN-US" class="hcp5"> &#160;for
guidance. &#160;BLU-BOBs and BLU-BIBs with a sticker on the rear panel showing
V1.05 or above are compatible with pull-down rates.</span></p>
<ul type="disc">
<li><p style="margin-left: 0px;">Crown amplifiers with PIP-BLU cards
fitted for BLU link audio transport are not currently supported for
BLU link networks with 'Sync to BNC' configured. &#160;LA will not
go online with a design which includes a PIP BLU and a Soundweb London
with 'Sync to BNC' configured</p></li>
</ul>
<p class="hcp6">&#160;</p>
<h3>Example: System designed to synchronise from the word clock at the
BNC input.</h3>
<p class="hcp7">The following example shows how to set
up a system which is designed to synchronise to an external word clock
which is running at the 48kHz pull-down sample rate of 47.952kHz.. </p>
<p class="hcp7">System components:</p>
<ul type="disc">
<li><p class="hcp7">BLU-800 Sync to BNC </p></li>
<li><p class="hcp7">BLU-800 Sync to BNC</p></li>
<li><p class="hcp7">BLU-320 Sync to BLU link</p></li>
<li><p class="hcp7">BLU-120, BLU-160, BLU-100, BLU-101,
BLU102</p></li>
</ul>
<p class="hcp6"><img src="100_Panel.png002.bmp" alt="" border="0" class="hcp2"></p>
<h4>&#160;</h4>
<h4>U1 &#160;- this device will be the master of the BLU link ring</h4>
In Properties,
<ul type="disc">
<li>Set the Sample Rate to 48kHz</li>
<li>Select the Sample Rate Pull-down 47.952kHz</li>
<li>Set BLU link Sync, to '<span class="hcp4">Sync to
BNC</span>'</li>
</ul>
<p>On the Device Control Panel</p>
<ul type="disc">
<li>Set the Mastership Priority to be higher than that set for all
other devices </li>
</ul>
<p>&#160;</p>
<p class="hcp6">U2 - this device will take over as the master
if there is an invalid BNC connection, or no BNC connected, to U1. &#160;Otherwise
it will sync to the BLU link ring</p>
<p>In Properties,</p>
<ul type="disc">
<li>Set the Sample Rate to 48kHz</li>
<li>Select the Sample Rate Pull-down 47.952kHz</li>
<li>Set BLU link Sync, to '<span class="hcp4">Sync to
BNC</span>'</li>
</ul>
<p>On the Device Control Panel</p>
<ul type="disc">
<li>Set the Mastership Priority to be lower than U1 but higher than
that set for all other devices </li>
</ul>
<p>&#160;</p>
<p class="hcp6"><span class="hcp4">U3 - this
device will synchronise from the BLU link network where U1 is the master</span></p>
<p>In Properties,</p>
<ul type="disc">
<li>Set the Sample Rate to 48kHz</li>
<li>Select the Sample Rate Pull-down 47.952kHz</li>
<li>Set BLU link Sync, to '<span class="hcp4">Sync to
BLU link</span>'</li>
</ul>
<p>On the Device Control Panel</p>
<ul type="disc">
<li>Set the Mastership Priority to be lower than U1 and U2 &#160;</li>
</ul>
<p>&#160;</p>
<p class="hcp6"><span class="hcp4">U4 and U5
- these devices will synchronise from the BLU link bus where U1 is the
master</span></p>
<p>In Properties,</p>
<ul type="disc">
<li>Set the Sample Rate to 48kHz</li>
<li>Select the Sample Rate Pull-down 47.952kHz</li>
<li>Set BLU link Sync, to '<span class="hcp4">Sync to
BLU link</span>'</li>
</ul>
<p>On the Device Control Panel</p>
<ul type="disc">
<li>Set the Mastership Priority to be lower than U1 and U2 &#160;</li>
</ul>
<p class="hcp6">&#160;</p>
<p class="hcp6">U7, U8 and U9 - these devices will synchronise
from the BLU link bus where U1 is the master</p>
<p>In Properties,</p>
<ul type="disc">
<li>Select the Sample Rate Pull-down 47.952kHz</li>
<li>Set BLU link Sync, to '<span class="hcp4">Sync to
BLU link</span>'</li>
</ul>
<p>On the Device Control Panel</p>
<ul type="disc">
<li>Set the Mastership Priority to be lower than U1 and U2 &#160;</li>
</ul>