Logic Source

MAIN00000176.gif
 
The Logic Source gives a high or low output depending on the state of its control panel. It can be set either manually using London Architect, from the logic control ports, or by being linked to another control. The Auto Off property will automatically set the Logic Source to OFF after a pre-defined ON period - this is especially useful in touch-panel designs as a method of de-bouncing the touch operation.
The light on the logic object design block indicates the current state of the output. This is operational in simulation and when online to the device.
 

Properties

MAIN00000177.gif
 
Auto Off (x 100ms)
Sets the time that the Logic Source remains high, in multiples of 100ms, e.g. when set to 10, it will remain high for 1 second.
 
Logic Source
Sets the the Logic Source ON or OFF. This is duplicated in the Logic Source control panel.
 

Control Panel

Double clicking on the Logic Source object will open the Logic Source control panel.
 
MAIN00000178.gif