Counter
Trigger
The output of the
Counter Trigger object will change to the ON state (high) once the number
of low to high transitions at the input match that of the Count value
under properties.
The output will
remain high until the reset (R) input has been turned on (goes high).
The output of counter will then go low and remain low (regardless of the
input value) until the reset input changes back to the OFF state (low).
The output of the counter will go high again once the number of low to
high transitions at the input match that of the Count value under properties.
The lights on the
logic object design block indicate the current state of the inputs and
output. These are operational in simulation and when online to the device.
Properties
Count
Sets the number
of input pulses to be counted before the output turns ON.